Heat pump running on emergency heat? What it means and what to do

Emergency (or auxiliary) heat uses electric resistance strips instead of the heat pump itself. It keeps you warm, but it's far more expensive to run — so if it's on all the time, something needs attention.

  • Free to call
  • No obligation
  • Line open 24/7
  • Quote before any work

Common causes

  1. Thermostat set to EM HEAT. Someone may have switched the thermostat to emergency heat. Set it back to regular HEAT and watch whether the outdoor unit runs.
  2. Normal backup during very cold weather. In a hard freeze, most heat pumps bring on auxiliary heat to help. Short bursts are normal; nonstop operation for days is not.
  3. Defrost problem. If the outdoor coil stays caked in ice for hours, the defrost control, sensor, or reversing valve may have failed.
  4. Low refrigerant. A leak reduces the heat pump's capacity, so the system leans on backup heat. Refrigerant leaks need a technician to find and repair.
  5. Outdoor unit not running. A failed capacitor, contactor, or fan motor can stop the outdoor unit entirely, leaving only the backup strips.

Smell gas or hear a carbon monoxide alarm? Leave the house first, then call from outside. If Atmos Energy is your gas company, its 24-hour leak line is 866-322-8667; otherwise call your gas utility or 911. Don't run the furnace again until it's been inspected.

When to call a pro

If the outdoor unit isn't running, stays iced over, or your electric bill has jumped while the house struggles to stay warm, call for a diagnostic.

Heat pump defrost and reversing valve repairs typically range from about $300 to $1,500; see our furnace and heating cost guide.

Check the contractor before work starts

Texas requires air conditioning and heating contractors to hold a license from the Texas Department of Licensing and Regulation (TDLR). Before you approve a repair:

  • Ask for the contractor's license number — Texas HVAC contractor licenses start with TACLA or TACLB.
  • Look it up on the TDLR license search to confirm it's active.
  • Get the diagnosis and price in writing before work begins, and ask whether the diagnostic fee is credited toward the repair.